Product code: PPS-LFP-24V-200Ah
A 25.6V (24V-class) 8S2P LiFePO4 battery pack with 200Ah rated capacity and 5.12kWh nominal energy, intended for compatible 24V-class residential solar hybrid inverters and backup systems.
*5-year limited warranty is a proposed commercial term, subject to final approval.
Rechargeable 8-series lithium iron phosphate battery pack for compatible 24V-class residential solar hybrid inverters and backup systems. Selected design: 25.6V nominal, 200Ah rated capacity, 5.12kWh nominal energy and basic 100A BMS.
The 100A BMS limits available current; stored energy is not continuous output power.
| Parameter | Specification | Notes |
|---|---|---|
| Chemistry | Lithium Iron Phosphate (LiFePO4) | Cell supplier/model to be recorded |
| Pack configuration | 8S2P; 16 × 3.2V 100Ah cells, or approved equivalent | Verify actual production BOM |
| Nominal voltage | 25.6V DC | 24V-class system |
| Rated capacity | 200Ah | At cell supplier test conditions |
| Nominal energy | 5,120Wh (5.12kWh) | 25.6V × 200Ah |
| Recommended usable energy | Approx. 4.10kWh DC | 80% design window; actual setting/warranty dependent |
| Charge voltage | 28.4–29.2V DC | 29.2V = 3.65V/cell; confirm cell limits |
| Recommended charge current | 40–80A | Subject to cell/BMS thermal limits |
| Maximum charge current | Up to 100A only if specifically approved | 100A discharge rating does not prove charge rating |
| Continuous discharge current | Up to 100A proposed | Subject to cell and BMS validation |
| Nominal continuous DC power | 2.56kW at 25.6V / 100A | Varies with voltage and temperature |
| Inverter low-voltage setting | Approx. 22.4V starting point | Coordinate with cell-level BMS cutoff |
| BMS cut-offs | Cell-based over/under-voltage thresholds | Set per cell maker and BMS supplier |
| Float / equalization | Float disabled or low standby; equalization OFF | Use LiFePO4 profile |
| Communication | Basic BMS; no external communication specified | No Bluetooth/CAN/RS485 claim |
| Feature | Specification / Requirement |
|---|---|
| BMS | Basic 100A class; verify separate charge and discharge ratings |
| Protection functions to verify | Cell over-voltage, cell under-voltage, over-current, short-circuit and temperature protection |
| Cell balancing | Depends on the fitted BMS; balancing type and current to be verified |
| Charge temperature | 0°C to 50°C proposed; below 0°C charging prohibited unless cell maker permits |
| Discharge temperature | -20°C to 55°C proposed; derate near limits |
| Storage | Cool, dry location; follow cell maker SOC and temperature instructions |
| Cooling | Natural convection; provide ventilation and clearance |
| Enclosure | Metal enclosure; IP rating not specified |
| Terminals | Insulated, polarity-marked DC terminals; current rating to be verified |
| External protection | Correctly rated DC fuse/breaker close to battery positive terminal |
| Cabling | Size for 100A continuous duty, cable length and voltage drop |
Illustrative home-backup guide: assumes 80% usable battery energy (4.096kWh DC) and 90% inverter efficiency, giving about 3.69kWh AC:
Actual runtime varies with load, temperature, inverter losses, battery age and BMS limits.
5-year limited warranty — proposed commercial term, subject to final approval. The final warranty card will define the start date, covered defects, capacity-retention threshold, cycle/throughput limit, operating conditions, exclusions and claim procedure.
Request a quote or ask about availability. Price on enquiry. Or call +919816992588.
Technical release note: This is a proposed specification, not a certified test report. Cell datasheets, BMS model/thresholds, current ratings, temperature cut-offs, enclosure dimensions/weight, fuse and terminal ratings, thermal performance and applicable Indian compliance are to be validated before production release. No BIS, IEC or UL certification is claimed.